ID 800H2

ID 800H2

Braking force F :
ID 800 20200 N at 100 bar
Dynamic torque :
F • (disc radius in m - 0.034) = Nm
Max pressure :
100 bar
Max total wear :
10 mm
Thickness of new lining :
17.5 mm
Continuous thermal capacity Qc :
2.5 kW
Hydraulic fluid :
Mineral oil based SAE/ISO 46
Total oil displacement for 2 mm movement of each pad :
0.01 dm3

COREMO ID 800 direct hydraulic brakes can be used in industrial applications which require regulation of the clamping force in response to variations in pressure.
The brake has an ON/OFF inductive sensor indicating opening and closure. An indicator warns of the maximum lining pad wear level. The brake operating temperature varies from -40 [°C] to + 200 [°C].

The Coremo Ocmea service is completed by reporting which includes calculations, FEM analyses and technical reports (all in English) supplied to the customer to complete the technical documentation of the machine on which the brakes are to be installed. This enables customers to make comments on the design variables and allows the Technical Department to adjust the design to provide the most suitable solution.